How to use OM-K6EDGE? read this manual instruction please.

Date: 2019-04-08 17:07:34

1, Open the bubble removal tank and find the water filter, install it first.

2, Check the lamination plate and blue seal ring, make sure no dirty on it.

3, Power on machine, check the emergency switch, it should be normally OFF.

4, Go to "Setting" Chinese is the last menu"参数设置" and select the language. Don't reset the other settings.

5, Enter the "Auto model", press "Start".

6, Default temperature setting is 55C degrees, temperature from 45 to 60 is good for lamination.

7, Different elevation has different maximum vacuum reading, we advise you to "Start" the machine and record the maximum reading of the left "Vacuum" meter, the setting value of the left "Vacuum" meter is the maximum value minus 1. (if maximum value we can get is -92, then the setting value is -91, if the maximum vacuum we can get is -98, then set the "vacuum" meter to -97), once finished setting this "Vacuum" at the first time, then you no need to reset it.

8, The right “Lamination” meter is for adjusting the laminating pressure, the default setting is -70.

9, If you want to increase the lamination pressure, click the blue button, it will appear in turn "L0-2","H1-2","P-1". The last "P-1" is for setting lamination pressure. the more value you set, the less pressure you get. (ex: -50 lamination pressure is bigger than -70).

10,Samsung flat LCD and iphone glass without frame set -50,glass face down, put a dust free wiper on the LCD for protecting the air bag.

11, When laminating framed glass for iphone, set lamination “-70”, glass face up. DON'T set over -70 (such as -50), otherwise it will damage LCD.

 

Warning: For “Vacuum” & “Lamination” monitor. Don’t press the blue button over 2 seconds, otherwise it will enter the advanced model

 

Normal issue: Why machine always keep pumping vacuum and never start the lamination step

 After click “Start”, Vacuum pump keep running more than 1 minute and never start the lamination, this is because the setting value of the “Vacuum” monitor is higher than the Maximum vacuum of this machine can pump, for example, if we set the “Vacuum” monitor -98, but the maximum vacuum the pump can reach is only “-96.5”, then the machine will always pumping unless it reach “-98”, so we have to set the “Vacuum” monitor to “-95.5”, then machine will work correctly

 

 

 

If you don't understand the relation between vacuum and elevation, please read the airticle by the click the above link.